WAND TM Sensors
WAND TM Sensors

WAND TM Sensors

Thin, embeddable, permanently installed, battery-free ultrasonic sensors

The WAND TM Sensors are designed to be permanently installed on the surfaces of pipework and vessels to provide reproducible thickness readings free of human error. Each sensor comes with an RFID for traceability and automated data management.

ÃÛÌÒ´«Ã½ offers the standard TM sensor, where the measurement point is in the centre of the sensor, or the offset TM sensor, where the measurement point is offset to the side for monitoring in places such as next to welds.

Technical Specifications

The TM Sensor comes in several configurations. ÃÛÌÒ´«Ã½ will recommend a design depending on the particular set of conditions such as temperature, material wall thickness, diameter, and curvature of the material.

Product Code

TMS-B5R (V4)

TMS-S5R (V7)

TMS-B5R-H2

Dimensions

65 mm OD, 1 mm thick

65 mm OD, 1 mm thick

65 mm OD, 1 mm thick

2.56 inches OD, 0.04 inches thick

2.56 inches OD, 0.04 inches thick

2.56 inches OD, 0.04 inches thick

Weight

6.5 g

6.5 g

6.5 g

0.23 oz

0.23 oz

0.23 oz

Operating Frequency

5 MHz

5 MHz

5 MHz

Minimum Thickness*

5 mm

3.5 mm+

5 mm

0.20 inches

0.14 inches +

0.20 inches

Maximum Thickness*

Up to 150 mm

Up to 50 mm

Up to 150 mm

Up to 5.91 inches

Up to 1.97 inches

Up to 5.91 inches

Minimum Specimen Diameter**

90 mm

50 mm

90 mm

3.54 inches

1.97 inches

3.54 inches

Transducer Active Area

5 × 12.5 mm

4 × 5 mm

5 × 12.5 mm

0.20 × 0.49 inches

0.16 × 0.20 inches

0.20 × 0.49 inches

Minimum Operating Temp

-40°°ä

-40°°ä

-40°°ä

-40°¹ó

-40°¹ó

-40°¹ó

Maximum Operating Temp***

130°°ä

130°°ä

180°°ä

266°¹ó

266°¹ó

356°¹ó

Sensor Resolution

<0.05 mm

<0.05 mm

<0.05 mm

<0.002 inches

<0.002 inches

<0.002 inches

Certifications

Ex ia IIC T4…T3 Ga (Ta = -40°°ä to +130°°ä/+150°C)

Ex ia IIC T4…T3 Ga (Ta = -40°°ä to +130°°ä/+150°C)

Ex ia IIC T4...T3 Ga Ta= -40°°ä to +120°C/+180°°ä

Ta = -40°°ä to +130°°ä/+150°C

Ta = -40°°ä to +130°°ä/+150°C

Ta = -40°°ä to +120°C/+180°°ä

Ta = -40°¹ó to +266°¹ó / +302°F

Ta = -40°¹ó to +266°¹ó / +302°F

Ta = -40°¹ó to +248°F / +356°¹ó

* Specifications based on flat plate measurements at room temperature may vary under operating conditions.

** For a straight pipe. The geometry affects the minimum diameter.

*** Above 90ËšC / 194ËšF, the minimum thickness that can be characterised by the sensor will increase. Please contact us for more details.

+ A sensor with the following specifications is available on request:

  • Minimum thickness of 2mm ( / Maximum thickness of up to 20mm / Maximum operating temperature of up to 110°C / 230°F